Home > News > news > Common faults and solutions fo.....
Contact us
The QC team is composed of skilled engineers and technicians.Working on CEFCC quality management system control, the QC system covers al...
Contact Now
Latest News

How to deal with the power failure of LCD advertising digital signage?

The LCD advertising displays is a new advertising communication platform, and the fields of use involve shopping malls, banks, transportation hubs, go...

It is very important to find the mainstream customer group of LCD advertising displays

Marvel, as a manufacturer of LCD advertising signage integrating production and sales, knows very well that it wants to make the company bigger and st...

Marvel's wonderful review of the ISE2020 in the Netherlands

The 2020 Netherlands International Professional Audiovisual and System Integration Exhibition (ISE 2020) was held on February 11 - 14 at the Amsterdam...

Marvel's wonderful review of the ISE2019 in the Netherlands

The 2019 Netherlands InternationalProfessional Audiovisual and System Integration Exhibition (ISE 2019) was heldon February 5-8 at the Amsterdam Inter...

Top 5 Display Trends – Digital LCD Display

Top 5 Display Trends – Digital LCD Display The current year's Consumer Electronics Show occurred in LasVegas not long ago. With exhibitors from every...

Few Ideas to Purchase LCD Display that you may have not known

Few Ideas to Purchase LCD Display that you may have not known In this advance era, innovation is simply gotten theeveryday feature on the highest poin...

Few Things That Will Help you to Make Reading on LCD More Easy for Eyes

Few Things that will Help you to make reading on LCD more Easy for Eyes Are you using an LCD screen? If yes then this article is foryou. There are man...

Marvel Make A Great Progress In ISE 2018

The 15th edition of ISE, held grandly at the RAI Amsterdam on 6-9 February 2017, is set to be the largest show in the fifteenth’s history. During fou...
Certifications
PRODUCT DISPLAY

News

Common faults and solutions for stand advertising player!

1. The screen of the vertical advertising machine flickers: In daily applications, the flickering display of the vertical advertising machine screen is a problem that users often encounter. In this regard, the user must first perform exclusion checks on external factors such as the magnetic field around the device, power supply voltage and other external factors. If it still cannot be used normally, it is necessary to perform a comprehensive check on the display's graphics driver to eliminate program installation problems. After the above operation is invalid, the user can also try to increase the refresh rate by 75HZ to see if it is feasible. If none of the above operations can achieve satisfactory results, professional assistance is needed, and the user needs to send the equipment to the repair station for inspection.

2. The vertical advertising machine does not respond after plugging in the power supply: The vertical advertising machine does not respond after plugging in the power supply is a problem that often occurs in practical applications. In this regard, the user can try to remove the advertising player, open the back cover of the advertising player, and check whether the dedicated power supply is energized, and whether the existing material is off or loose. The specific method: whether the indicator light is on when using the multi-meter, if it is normal, it means that the power supply is powered. The power supply problem is ruled out, and the user should check the power supply of the decoder board, advertising player drive board, high voltage bar, speaker, and LCD screen in turn.

3. There is no display on the screen, and the indicator on the front panel is flashing: After this problem occurs, the user should check whether the signal line connection between the display and the computer is firm, and check whether the signal line connector is broken or bent or damaged.

4. The screen is black and displays "Signal out of sync range" or "OUT OF RANG": This phenomenon is a thorny problem that users often see in practical applications. Generally, the signal sent by the computer exceeds the display range of the monitor, and the monitor detects It is caused by abnormal signal stop working. In this regard, the user can try to restart the monitor and reset the output frequency of the computer.

5. Thumb-sized black spots appear on the LCD screen: This phenomenon is mostly caused by external force squeezing. Under the pressure of external force, the polarizer in the liquid crystal panel will deform. This polarizer is like aluminum foil. It will not bounce up after being recessed. This causes the difference in reflection of the liquid crystal panel, and the dark part will appear. Part of it is easy to find under the white screen, and the general size is more than ten square millimeters, which is the size of a thumb. Although this phenomenon will not affect the service life of the LCD screen, users should pay more attention not to press the LCD screen with their fingers.